Files
cc-ci-orchestrator/scripts/recovery

Recovery tooling — permanent home

Promoted from /tmp ad-hocery after the 2026-08-03 cc-ci 26.05 outage (see .cc-ci-logs/server-update-2026-08-03.md and the hetzner-server-recovery skill, which is the procedure; these are the tools it uses).

Tool What it does
hetzner.py <server> <cmd> Hetzner Cloud API: status, actions, reboot/reset/poweroff/poweron, rescue-on/off, console credentials. Knows cc-ci (134485294) and orchestrator (134487234) by name.
hetzner-console.sh <server> screenshot|key|type Shell-only access to the VGA console: fresh console session → websocat bridge → vncdotool (venv auto-bootstrapped at ~/.cache/hetzner-console-venv).

Token: HCLOUD_TOKEN env, or /srv/cc-ci/.hcloud-token (chmod 600). Not in git, not in .testenv. Prefer per-incident tokens and revoke after — and never paste tokens into chat transcripts (the 2026-08-03 incident token was pasted mid-incident and had to be flagged for rotation).

The 10-minute unreachable-server drill (condensed from 2026-08-03)

  1. hetzner.py cc-ci status — "running" + no SSH/ping means booted-but-broken, not crashed.
  2. hetzner-console.sh cc-ci screenshot /tmp/console.png — look at the actual screen: which generation booted? login prompt or emergency shell?
  3. Plain reboot first. If the default boot is the broken generation, DON'T fight GRUB timing over VNC — go to rescue: rescue-on → poweroff → wait status=off → poweron → ssh root@<public-ip> (key 113082420 = ~/.ssh/cc-ci-root-ed25519; fresh UserKnownHostsFile).
  4. In rescue: mount /dev/sda1 /mnt and fix the boot default:
    • Generations live in a GRUB submenu: entry ids are 1>N (top level: 0 = default entry, 1 = the submenu). A bare index like 2 silently falls back to the broken default.
    • Persistent: grub-editenv /mnt/boot/grub/grubenv set 'default=1>N' (survives reboots).
    • Clear it after the next successful nixos-rebuild switch — the regenerated grub.cfg shifts indices and a stale override points at the wrong generation.
    • Journal of the failed boot: journalctl -D /mnt/var/log/journal --list-boots / -b <id>.
  5. rescue-off → poweroff → poweron → verify → write the incident up in data/cc-ci/JOURNAL.md and (if server) .cc-ci-logs/.

Prevention: nixos-rebuild test before switch, always (see AGENTS.md / the update skills) — test leaves the bootloader alone, so a power-cycle recovers by itself.