Through row 116
This commit is contained in:
parent
857634d1f1
commit
2fb4f8771c
@ -329,6 +329,7 @@ class LongCaseStudyForm(BaseCaseStudyForm):
|
||||
'power_technology',
|
||||
'power_technology_other',
|
||||
'energy_storage_capacity',
|
||||
'energy_transmission_capacity',
|
||||
'maximum_power_output',
|
||||
'discharge_time',
|
||||
'contractor_or_supplier_of_technology',
|
||||
|
@ -661,37 +661,22 @@ class CaseStudy(models.Model):
|
||||
|
||||
# 2.2.1.4
|
||||
power_technology_other = models.CharField(
|
||||
verbose_name=_("Other power technology"),
|
||||
help_text=_("Please specify the power technology."),
|
||||
verbose_name=_("Further information about power technology"),
|
||||
max_length=128,
|
||||
blank=True
|
||||
)
|
||||
|
||||
# 2.2.2
|
||||
energy_storage_capacity = models.DecimalField(
|
||||
verbose_name=_("Energy storage capacity"),
|
||||
help_text=_("Enter the total capacity of the energy storage system in kilowatt-hours (kWh)."),
|
||||
verbose_name=_("Total storage capacity (kWh)"),
|
||||
max_digits=20,
|
||||
decimal_places=3,
|
||||
blank=True,
|
||||
null=True,
|
||||
)
|
||||
|
||||
# 2.2.2.1
|
||||
maximum_power_output = models.DecimalField(
|
||||
verbose_name=_('Maximum power output'),
|
||||
help_text=_('Enter the maximum power output of the storage system in kilowatts (kW).'),
|
||||
max_digits=12,
|
||||
decimal_places=3,
|
||||
blank=True,
|
||||
null=True,
|
||||
)
|
||||
|
||||
# 2.2.2.2
|
||||
discharge_time = models.DecimalField(
|
||||
verbose_name=_('Time for discharge from full capacity'),
|
||||
help_text=_('Enter the time it takes to discharge from full capacity at maximum power output (in hours).'),
|
||||
max_digits=6,
|
||||
energy_transmission_capacity = models.DecimalField(
|
||||
verbose_name=_("Total transmission capacity (kW)"),
|
||||
max_digits=20,
|
||||
decimal_places=3,
|
||||
blank=True,
|
||||
null=True,
|
||||
@ -700,7 +685,7 @@ class CaseStudy(models.Model):
|
||||
# 2.2.3
|
||||
contractor_or_supplier_of_technology = models.CharField(
|
||||
verbose_name=_('Contractor and/or supplier of technology'),
|
||||
help_text=_('List companies that act as contractors or suppliers of technology related to energy storage.'),
|
||||
help_text=_('List companies that act as contractors or suppliers – e.g. Siemens Gamesa, GE, Alstom, Vestas, Hanwha Q CELLS, Mitsubishi, First Solar, Jinko Solar, Trina Solar, Suzlon Energy, Statkraft, Shanghai Electric, Ballard Power Systems, Panasonic, etc'),
|
||||
max_length=256,
|
||||
blank=True
|
||||
)
|
||||
@ -715,10 +700,12 @@ class CaseStudy(models.Model):
|
||||
)
|
||||
|
||||
# 2.2.5
|
||||
additional_technical_details = models.CharField(
|
||||
additional_technical_details = models.TextField(
|
||||
verbose_name=_("Additional technical or economic details"),
|
||||
help_text=_("Add any additional details such as: length, from-to, voltage, substations etc"),
|
||||
max_length=512,
|
||||
help_text=_("Add any additional details such as: length, from-to, voltage, \
|
||||
substations, power output, (dis)charge rates, how this technology or \
|
||||
project interacts with the energy system (e.g. provides reactive power \
|
||||
to ensure power supply in phase etc.)"),
|
||||
blank=True
|
||||
)
|
||||
|
||||
|
@ -301,16 +301,10 @@ dd ul { padding-left: 0; margin-left: 0; }
|
||||
{{ case_study.energy_storage_capacity }} TODO UNITS?
|
||||
{% endif %}
|
||||
|
||||
{% if case_study.maximum_power_output %}
|
||||
<dt>{% trans "Maximum power output" %}:
|
||||
<dd id="maximum_power_output">
|
||||
{{ case_study.maximum_power_output | intcomma }} W
|
||||
{% endif %}
|
||||
|
||||
{% if case_study.discharge_time %}
|
||||
<dt>{% trans "Time for discharge from full capacity" %}:
|
||||
<dd id="discharge_time">
|
||||
{{ case_study.discharge_time | intcomma }} {% trans "seconds" %}
|
||||
{% if case_study.energy_transmission_capacity %}
|
||||
<dt>{% trans "Energy transmission capacity" %}:
|
||||
<dd id="energy_transmission_capacity">
|
||||
{{ case_study.energy_transmission_capacity }} TODO UNITS?
|
||||
{% endif %}
|
||||
|
||||
{% if case_study.contractor_or_supplier_of_technology %}
|
||||
|
@ -40,6 +40,14 @@
|
||||
|
||||
<!-- Conditional logic for hiding and un-hiding fields. -->
|
||||
<script>
|
||||
function showIf(thingToShow, whetherToShowIt) {
|
||||
if (whetherToShowIt) {
|
||||
$(thingToShow).show()
|
||||
} else {
|
||||
$(thingToShow).hide()
|
||||
}
|
||||
}
|
||||
|
||||
// Here we define the fields we need to conditionally toggle.
|
||||
// TODO: Move this knowledge out of the template
|
||||
var conditionalFields = [
|
||||
@ -102,13 +110,25 @@
|
||||
name: "power_technology",
|
||||
redraw: function() {
|
||||
const other = document.getElementById('id_id_power_technology_0_4')
|
||||
const showHide = document.getElementById('div_id_power_technology_other')
|
||||
const panel = document.getElementById('div_id_power_technology_other')
|
||||
|
||||
if (other.checked) {
|
||||
$(showHide).show();
|
||||
} else {
|
||||
$(showHide).hide();
|
||||
showIf(panel, other.checked)
|
||||
}
|
||||
},
|
||||
|
||||
{
|
||||
name: "power_technology",
|
||||
redraw: function() {
|
||||
const group = document.forms['case-study-form'].power_technology
|
||||
|
||||
// Storage / other
|
||||
let showStorage = ['ES', 'OT'].includes(group.value)
|
||||
|
||||
// Transmission / heat / other
|
||||
let showTransmission = ['PT', 'HN', 'OT'].includes(group.value)
|
||||
|
||||
showIf('#div_id_energy_storage_capacity', showStorage)
|
||||
showIf('#div_id_energy_transmission_capacity', showTransmission)
|
||||
}
|
||||
},
|
||||
|
||||
@ -134,11 +154,7 @@
|
||||
const input = document.getElementById(option.input)
|
||||
const section = document.getElementById(option.section)
|
||||
|
||||
if (input.checked) {
|
||||
$(section).show();
|
||||
} else {
|
||||
$(section).hide();
|
||||
}
|
||||
showIf(section, input.checked)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user